(914 mm). Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Asphalt shingles shall be used only on roof. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Drip edges shall extend not less than. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. The installation of liquid-applied roofing shall comply with the provisions of this section. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. The installation of wood shakes shall comply with the provisions of this section. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A 792, ASTM A 875, ASTM A 463, or ASTM A 653. References are to the 2018 International Residential Code (sections are designated as R). The lecture and activity format allows participants to discuss the changes, reasons for the changes, and answer knowledge review questions. Stainless steel fasteners are acceptable for metal roofs. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. The second R-value applies when more than half of the insulation is on the interior of the mass wall. Foam plastic materials and installation shall comply with. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. Asphalt shingles shall meet the classification requirements of Table 905.2.4.1 for the appropriate ultimate design wind speed. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. Galvanized fasteners shall be used for steel roofs. Thermoset single-ply membrane roofs shall have a design. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right Wood shingles shall be laid with a side lap not less than 1, Roof flashing shall be not less than No. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Interlayment shall comply with ASTM D226, Type I. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Plywood is a wood structural panel covered in R803.2.2 which points you to R503.2.1.1 There is a lot of cross over between chapters 5, 6, and 8, so don't just go with the chapter titles of floor, wall, roof. Section R804 Cold-Formed Steel Roof Framing Section R806 Roof Ventilation Section R807 Attic Access Chapter 9 Roof Assemblies A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Asphalt shingles shall be fastened to solidly sheathed decks. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. 0
Self-adhering polymer-modified bitumen. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. are not required for roofs sheathed with lumber having a nominal width of less than 3 feet Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. The installation of wood shakes shall comply with the provisions of this section. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Asphalt shingle packaging shall bear a. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. 3. Interpretation #: CEB-2018-10-2005-IRC-R905.2.1 Building or Fire Safety Law Interpreted 675 IAC 14-4.3, the 2005 Indiana Residential Code. 2 RESIDENTIAL ROOFING GUIDE 2018 IRC. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Roof Sheathing Ring Shank nails have been added to Table R602.3(1) Fastening Schedule with the designation RSRS-01 (2-3/8" x 0.113") as an option for roof sheathing attachment. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. The framing assembly incudes horizontal braces, vertical retrofit studs, and compression blocks. Mineral-surfaced roll roofing shall conform to ASTM D 3909 or ASTM D 6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall be fastened to solidly sheathed decks. The installation of slate shingles shall comply with the provisions of this section. The International Residential Code (IRC) and the Residential Edition of the Florida Building Code (FBC) both refer to Table R503.2.1.1(1) of the APA Engineered Wood Construction Guide for specs. Valley flashing shall be not less than 15 inches (381 mm) wide. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Table R803.1 is for roof sheathing which requires 5/8 plywood with rafters 24" o.c. Sprayed polyurethane foam roofs shall have a design. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Asphalt shingle packaging shall bear a. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. arrow_right. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. IRC Section 301.3 Story Height: The ability is restored to construct a story of a dwelling using 12-foot high bearing walls if the wall studs are engineered for gravity loads, wall bracing amounts are increased, and a roof or celling diaphragm provides support to the studs. The GAF VersaShield Fire-Resistant Roof Deck Protection may be placed under or over the counterbattens. Where required, ice barriers shall comply with Section 905.1.2. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Galvanized fasteners shall be used for steel roofs. arrow_right. Asphalt shingles shall be fastened to solidly sheathed decks. Valley flashing shall be not less than 15 inches (381 mm) wide. Slate shingles shall comply with ASTM C406. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Asphalt shingle packaging shall bear a. Where the existing roof has two or more applications of any type of roof . The installation of thermoset single-ply roofing shall comply with the provisions of this section. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Interlayment shall comply with ASTM D226, Type I. A base sheet that complies with the requirements of Section 1507.11.2 of the. Wood shakes shall comply with the requirements of Table R905.8.5. The installation of liquid-applied roofing shall comply with the provisions of this section. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with Section 703.8.2.2. Liquid-applied roofing shall be installed in accordance with this chapter and the. R905.2.1 Sheathing requirements. 12 oz/sq ft for preformed metal shingle systems. SECTION R803 ROOF SHEATHING. The installation of modified bitumen roofing shall comply with the provisions of this section. A new Footnote j Mineral-surfaced roll roofing shall not be applied on roof. Drip edges shall extend not less than. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. A base sheet that complies with the requirements of. 2018, 2021 IECC: Mass walls shall be in accordance with Section R402.2.5 (N1102.2.5 in 2018 IRC). Where the roof, Where required, ice barriers shall comply with. Valley flashing shall be not less than 15 inches (381 mm) wide. Asphalt shingles shall be tested in accordance with ASTM D7158. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. %%EOF
Where exterior plaster or adhered masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and Section 703.6.3. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Nails shall be corrosion resistant and not less than 11 gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Asphalt shingles shall be used only on roof. Asphalt shingles shall be used only on roof. Each bundle of shakes shall be identified by a. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. The installation of mineral-surfaced roll roofing shall comply with this section. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Roof penetrations shall be flashed and sealed in accordance with this chapter. Thermoplastic single-ply membrane roofs shall have a design. (R803.1) Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of sections R905.7 and R905.8. Galvanized fasteners shall be used for steel roofs. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Sprayed polyurethane foam roofs shall have a design. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. 12 oz/sq ft for preformed metal shingle systems. (R803.1) Spaced lumber sheathing is not allowed in Seismic Design Category D 2. or less, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. The installation of thermoset single-ply roofing shall comply with the provisions of this section. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Wood shakes shall comply with the requirements of Table R905.8.5. Slate shingles shall comply with ASTM C 406. The installation of wood shakes shall comply with the provisions of this section. over the entire roof and over the 4-inchwide (102 mm) membrane strips and. In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. satisfy the requirements of 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511, 2012, 2009 and 2006 IBC Section 1510, 2018 and 2021, 2018 and 2015 IRC Section R908 or 2012, 2009 or 2006 IRC Section R907. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Base and cap flashing shall be installed in accordance with manufacturer's instructions. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. The installation of mineral-surfaced roll roofing shall comply with this section. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Liquid-applied roofing shall have a design. Asphalt shingles shall be fastened to solidly sheathed decks. Roof valley flashing shall be not less than No. Section R803 Roof Sheathing R803.2 Wood Structural Panel Sheathing (Roof Online Note: This subsection covers plywood and OSB sheathing. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. The installation of liquid-applied roofing shall comply with the provisions of this section. 12 oz/sq ft for preformed metal shingle systems. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. 1. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D 3909 or ASTM D 6380 Class M, shall be permitted. 3. the 2018 International Residential Code (IRC) simplified wall bracing requirements. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. A base sheet that complies with the requirements of. Install 7/16 in.-structural sheathing (OSB or plywood) on the vertical face of the gable end wall. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of built-up roofs shall comply with the provisions of this section. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. . Water soaked or deteriorating decking must be replaced. conditions about your roof that may limit your product choices or affect the cost of your roofing job. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Underlayment for asphalt shingles, clay and concrete tile, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles, wood shakes and metal roof panels shall conform to the applicable standards listed in this chapter. R905.2Asphalt shingles. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. endstream
endobj
202 0 obj
<. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Glenn 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing.